선형 급격한 온도 변화 테스터 비우기 및 채우기 지침
Before starting the linear rapid temperature change tester, check whether the relevant protective measures are in place, such as fire protection, protection, leak prevention and other tools. Check whether the power supply is in place according to the power supply installation and equipment grounding, whether the phase sequence is correct, and whether the grounding is good. Then power on the equipment, and then check whether the relevant valve is open. Otherwise, the circulating pump will be blocked and burned out, or the pipeline pressure will be too large to crack the pipeline.
The linear rapid temperature change tester drains the liquid, and the liquid addition and emptying are performed simultaneously. The linear rapid temperature change tester device is located at the upper end of the device, closed clockwise, and opened counterclockwise. The linear rapid temperature change tester exhaust valve is located on the side of the unit. Use the auxiliary tool to insert a hole, turn it clockwise, and open it counterclockwise.
The linear rapid temperature change tester can cause damage to the circulation pump if it is not filled with the circulating heat transfer medium in accordance with the following simple operation guide. The linear rapid temperature change tester needs to pay attention to the necessary protective measures, wearing rubber gloves, goggles, eye wash, etc., to ensure that the thermal medium meets the system requirements (temperature range, viscosity, corrosion, toxicity). Check the medium to ensure no precipitation, no color, no corrosiveness. If a small amount of sediment should be settled stably, the precipitate should not be added to the system when a heat transfer medium is added. The linear rapid temperature change tester should be splashed when dumping, and always pay attention to the sight glass on the side of the device to prevent the overflow into the electrical cabinet and damage the equipment and form pollution. Before adding the liquid, check whether the relevant pipeline is completely open. Whether the liquid port is closed.
If the linear rapid temperature change tester mixes different types of thermal fluid in the thermal fluid circulation, the linear rapid temperature change tester will be damaged. Different types of thermal fluids (eg mineral oil, silicone oil, synthetic oil, water, etc.) cannot mix with each other in the thermal fluid circulation. When replacing other types of thermal fluid, the thermal fluid circulation must be flushed. The previous thermal fluid is not allowed to remain in the thermal fluid circulation.
The linear fast temperature change tester’s emptying liquid is as shown above. After the process of emptying and adding liquid, the power can be turned on and the linear rapid temperature change tester can operate normally.
관련 추천
-
Is the centrifugal pump or the volumetric pump selected in the pharmaceutical laboratory?
1891In the pharmaceutical laboratory, a variety of refrigeration equipment is used more, then as a more common equipment - pumps, mainly centrifugal pumps, volumetric pumps. Then, the user friend should have a better understanding of their performance...
세부 정보 보기 -
How to troubleshoot the failure of the material aging test chiller?
2178Regular maintenance work for the material aging test chiller, and troubleshooting is also very important. 1. Exhaust at double high pressure, heat dissipation may be problematic. When it is detected that the high and low pressure of the system are...
세부 정보 보기 -
산업용 냉각기 시스템 선택 방법
2181산업용 냉각기 시스템을 구매하고 싶으신가요? 신뢰할 수 있는 산업용 워터 칠러 시스템을 구매하고 싶으신가요? 고품질 산업용 냉각기 시스템을 구입하고 싶으십니까? 구매 방법?1. 공정 요구 사항 장비에 관계없이 LNEYA는 사용자에게 위트 ...
세부 정보 보기 -
저온 냉각기는 어떤 산업에 도움이 될 수 있나요?
1763저온 냉각기 제품에 대해 잘 모르시는 분들도 계실 겁니다. 저온 냉각기는 산업 생산에 사용되는 일종의 전문 냉동 장비입니다. 최근 몇 년 동안 다양한 유형의 저온 냉각기에 대한 수요가 많았습니다.
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan