There are usually three ways to control the temperature of laboratory reactors
1. Manual control: Manually operate the knob on the front of the reactor controller.
2. Control by PC: The PC and the controller are connected by a network cable, and the operation is carried out on the PC.
3. Controlled by thermostat: Silicone oil is heated through the thermostat, and the thermostat naturally has a temperature control function. Although the thermostat heating limit (usually 250°C) is not as high as that of electric heating (can be as high as 400-500°C), the thermostat rises and falls smoothly, and the low temperature can reach -60/-80°C.
Our LNEYA laboratory reactor temperature control system belongs to the third category. However, the temperature control range is from -120 degrees to 350 degrees. It adopts a fully enclosed pipeline design and a high-efficiency plate heat exchanger, which reduces the demand for heat transfer oil, improves the heat utilization rate of the system, and realizes rapid temperature rise and fall. Continuous temperature control can be achieved in the temperature range of minus 90 degrees to 195 degrees and minus 70 degrees to 220 degrees without pressure.
Jacketed glass reactors are popular in current chemical experiments. The supporting temperature control equipment has also become a matter of widespread concern in the industry. It is known that the cooling and heating temperature in the reaction process has an absolute influence on the reaction process and results. The analysis of the temperature control equipment’s ability to increase and decrease the temperature of the material has become the basic basis for choosing chiller. Then the cooling and heating capacity is not only estimated by imagination and experience, but requires scientific analysis and calculation methods, and needs to calculate the required heating power and cooling power according to the heating rate and cooling rate.
When our technicians communicate with customers, they will first understand the requirements of engineering parameters, such as high and low temperature, how long is the temperature control time, etc., so as to calculate the cooling power and heating power of the chiller required, and determine the available chiller. model, to give customers the most complete temperature control solution. If you also have this need, you can contact us.
관련 추천
-
실험실에서 냉난방 장비 사용의 이점
2235실험실 냉난방 장비 (냉난방 통합 기계, 냉동 및 가열 사이클 장치라고도 함)는 냉난방, 난방 및 냉방을 신속하게 변환 할 수 있고 동일한 매체 (...)를 통합하는 장치입니다.
세부 정보 보기 -
수직형 초저온 냉장고의 열전달 효과가 감소하는 이유
2267If the outer frost layer of the vertical ultra-low temperature refrigerator is too thick or excessively dusty, it can be caused because the external temperature of the evaporator is mostly lower than 0 °C, resulting in low heat transfer efficiency...
세부 정보 보기 -
고온 저온 테스트 챔버의 가격 분석
1998속담에 "지불한 만큼 얻는다"는 말이 있습니다. " 고온 저온 테스트 챔버의 가격은 구성의 품질과 관련이 있습니다. 우시 LNEYA의 기술 자체는 귀중합니다. 테스트 챔버 산업에서 고온 저온은 ...
세부 정보 보기 -
화학 산업에서 산업용 냉각기의 디버깅 단계
1886After completing the installation of industrial water chillers in chemical enterprises, certain debugging needs to be carried out in the early stage of operation. Only through careful debugging can we find out whether there are hidden troubles in...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan