The ultra-high temperature material impact test chamber test device has too much frozen oil in the evaporator, which can also cause insufficient cooling and cause slow cooling. The oil stored in the evaporator of the ultra-high temperature material impact test chamber test device can be directly judged by the hot and cold boundary line of the oil surface. If the oil level is too high, it should be released in time.
Some Freon and refrigerating machine oil dissolve each other. Therefore, when the refrigerant in the refrigeration system of the ultra-high temperature material impact test chamber test device is circulating, it is inevitable that the refrigerating machine oil will remain in the various components, and the residual oil in the heat exchanger will affect Heat transfer coefficient. Especially when the refrigerating machine oil enters the evaporator of the test device, if the structural design or installation is unreasonable, the ultra-high temperature material impact test device will only enter or reduce the refrigerating machine oil, so that the residual refrigerating machine oil in the evaporator is more The more you come, the more serious the heat absorption effect, and the lack of cooling capacity. If you don’t handle it at this point, the temperature will not drop. Therefore, you must carry out the oil draining work.
How to judge that the ultra-high temperature material impact test chamber test device has more refrigeration oil in the evaporation tube and affects the refrigeration is a difficult thing. In the case of the ultra-high temperature material impact test device, there is a significant anomaly, that is, the hoarfrost on the evaporation tube is sparsely pulled, incompletely formed, and is defrosted, if there is no other fault, then It is likely that there is too much residual refrigeration oil in the evaporator tube. To remove the freezer oil in the evaporator of the ultra-high temperature material impact test chamber test device, it must be removed, purged and dried. For the tube type evaporator, it is inconvenient to disassemble, the inlet of the test device evaporator can be blown with compressed air, and then the tube is baked with a blowtorch.
There are also many types of evaporators for the ultra-high temperature material impact test chamber test device. Once there are more refrigeration oils, we need to solve them in time.
관련 추천
-
LNEYA 신에너지 전기 자동차 테스트 온도 제어 냉난방 솔루션
2214With the gradual electrification of the automotive industry, the new energy vehicle market has entered a stage of rapid development. The battery is the heart of new energy vehicles, and charging is the source to ensure their operation. Therefore, ...
세부 정보 보기 -
반도체 레이저 자동 온도 제어 장비 액세서리 결함 솔루션
2159반도체 레이저 자동 온도 제어 압축기 프로스팅, 순환 물 순환 또는 밸브가 열리지 않을 수 있으며, 물 밸브, 모든 파이프 라인을 확인하여 원활하게 단락 파이프 라인을 설치하십시오. 서큘라틴이 ...
세부 정보 보기 -
고온 실리콘 오일 냉각 및 가열 사이클 기계 유지보수 단계
1834고온 실리콘 오일 냉각 및 가열 사이클 기계의 기계적 마모는 냉동 용량에 직접적인 영향을 미치는 중요한 요소입니다. 사용 중에 작동 매개 변수를 기록해야하며 종종 ...
세부 정보 보기 -
How to Choose Water Chiller Units in Small Factories
2198Professional water chiller factory said that the quality of equipment can be seen from the three main components of small water chiller units. The most important one is the compressor, which is the heart of the unit and the most critical component...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan