Immersion phase change liquid cooling system
A large amount of data throughput and calculation makes the data center, which is the “brain” of emerging technologies such as artificial intelligence and big data, face unprecedented challenges in energy consumption and heat dissipation. Liquid cooling technology and liquid cooling data centers for equipment such as liquid cooling servers have emerged as the times require.
In the working state, each heating component will generate heat, causing the coolant to heat up. When the temperature of the cooling liquid rises to the boiling point corresponding to the system pressure, the cooling liquid undergoes a phase change, changing from a liquid state to a gaseous state, and absorbs heat through the heat of vaporization to realize heat transfer, which is the most energy-saving and efficient refrigeration in liquid cooling model.
Immersion cooling medium (such as fluorinated liquid), special cooling liquid has high insulation, low viscosity, non-flammable characteristics, and can ensure chemical inertness and stability within the operating range. However, due to the price and loss of fluorinated liquid media, the overall operating cost is high. Our LNEYA liquid-liquid circulation distribution cooling system was born specifically for this situation, which greatly reduces the loss of fluorinated liquid.
The core components of the cold plate liquid-cooled server effectively reduce the PUE of the data center.
Among the eight major nodes of the computing hub in the future, the PUE of large and above data centers in East China and large and above data centers in western regions with a favorable climate should drop below 1.25. Due to its obvious advantages, liquid cooling has become the main cooling technology for data centers. Among them, the cold plate liquid cooling technology is mature and ecologically perfect. As the core component of the cold plate liquid cooling server, the cold plate also plays an important role in effectively reducing the PUE of the data center.
Liquid-cooled data centers should take comprehensive reliability measures at all levels of servers, cabinets and micro-modules. LNEYA cold plate liquid cooling modular data center solution takes a single module as a unit, integrates IT cabinets, power distribution units, closed components, refrigeration units, wiring and other functionally independent units to realize the complete functions of the data center. It can be flexibly disassembled and transported, which not only saves the space of the computer room but also expands the class, and realizes rapid deployment in batches.
7 * 24 무료 상담 및 종합 솔루션 제공


이메일: sales@lneya.com
WhatsApp: 086 13912479193
관련 추천
-
LNEYA data center liquid cooling solution Liquid Cooled CDU Distribution Unit
2417LNEYA data center liquid cooling chiller CDU
세부 정보 보기 -
Introduction to cold plate liquid cooling system products and equipment
2058Introduction to cold plate liquid cooling chiller
세부 정보 보기 -
Water chiller for high and low temperature testing of aviation fuel
1580High and low temperature cooling of aviation fuel usually requires the use of water-cooled chillers rather than air-cooled chillers. This is because water-cooled chillers have higher energy efficiency and better temperature control accuracy, and a...
세부 정보 보기 -
액체 냉각 냉각기(에너지 저장)
5085Model CNYL -45~55 Cooling Capacity 45KW Temperature Control Accuracy ±0.5℃ Real-time temperature record Secondary Refrigerant Ethylene glycol antifreeze, fully enclosed design of refrigerant circulation system Refrigerant R410A Flow 300L/min~400L...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan












상담 신청하기
24시간 이내에 답변 드리겠습니다.