Industry and introduction of low temperature chiller
In petroleum refining, petrochemical industry, organic synthesis, chemical products and other industrial production, refrigeration technology must be applied to control the reaction temperature during processes such as liquefaction, condensation, solidification, separation, refining, crystallization, concentration, and purification.
The chemical industry is mainly used for the cooling and cooling of chemical reaction kettles, and takes away the ordinary heat generated by chemical reactions in time to reach the purpose of cooling (cooling), in order to improve product quality. If the cold water (wind) provided by the refrigerator is used for cooling, not only the product quality can be greatly improved, but also the consumption efficiency can be improved. The pharmaceutical industry is mainly used to control the temperature and humidity of the workshop and to take out the heat of reaction during the process of consuming the drug substance.
Refrigerators in the industry are basically composed of components such as evaporators, single-stage compressors, oil separators, condensers, and liquid storage tanks. LNEYA’s freezer has exclusive technology, the temperature range is -5 ℃ ~ -150 ℃, which can meet different temperatures. This cooler uses international brand Carrier compressor, adopts automatic cascade refrigeration mode and mixed refrigerant, direct cooling ultra-low temperature freezer, single compressor automatic cascade refrigeration technology can freeze to minus 120 ° C in 3 minutes. Before delivery to customers, the production workshop provides machine installation and system testing. Users only need to complete the installation of refrigerant and cooling water.
The working principle of LNEYA low temperature chiller is as follows:
low temgperature chiller appearance:
Verwandte Empfehlungen
-
Es gibt in der Regel drei Möglichkeiten, die Temperatur von Laborreaktoren zu kontrollieren
18011. Manuelle Steuerung: Manuelle Bedienung des Drehknopfes an der Vorderseite des Reaktorsteuergeräts.2. Steuerung über PC: Der PC und der Regler sind über ein Netzwerkkabel verbunden, und die Bedienung erfolgt über den PC.3. Gesteuert durch Thermostat: Silikonöl...
Details anzeigen -
Cooling method for laboratory evaporative instruments in operation
1793Choosing the right cooling method for an evaporation experiment can have an unimaginable impact on overall system performance, economy, and efficiency. It is necessary to purchase cooling water circulation machine as supporting equipment. When pu...
Details anzeigen -
High and low temperature alternating wet heat shock test box function description
1904Consumers need to pay attention to the performance of the high and low temperature alternating wet heat shock test chamber. LNEYA's test chamber is closer to the needs of the purchasing company. The high and low temperature alternating heat and hu...
Details anzeigen -
The solution to the fully enclosed heating and cooling thermostat lack of refrigerant alarm
2333What should I do if the fully enclosed heating and cooling thermostat alarms for lack of refrigerant? I believe that many customers will encounter this problem when they use it. In fact, this is relatively simple. As long as we know the principle ...
Details anzeigen