Semiconductor production process and testing process temperature control equipment
Use fluid fluorinated liquid for temperature control (minimum -100 degrees)
Gas cold and hot rapid temperature change thermal chuck
Low temperature gas cooler -120 degrees
Direct cooling cooling unit (-150 degrees)
The heating method within 40°C is heated by compressor hot air.
The Chiller ring system adopts a fully enclosed design and a magnetic drive pump.
Chiller100% helium detection, 100% safety inspection, to ensure safety and reliability.
chiller100% after 24 hours of continuous operation copy machine.

Verflüssiger: micro-channel heat exchanger (air-cooled) plate heat exchanger (water-cooled)
Verdampfer: Plate heat exchanger Throttling device: Electronic expansion valve Circulation system: The whole system is a fully closed system, low temperature does not absorb moisture in the air, does not volatilize heat transfer medium, low temperature automatically replenishes heat transfer medium into the circulation system.
Shell material: cold-rolled plate spray RAL7035
Inside the pipeline: including stainless steel SUS304, copper, ceramics, broken silicon, silicone sealant, PTFE
Control system: PLC programmable controller
Communication protocol: RS485 interface Modbus RTU protocol
Ethernet-Schnittstelle TCP/IP-Protokoll
Operation interface: LNEYA customized 7-inch color touch factory temperature curve display\EXCEL data export
Die Pumpe mit variabler Frequenz kann den Druck und den Durchfluss des Hydraulikkreislaufs einstellen
The output pressure and flow rate of circulating fluid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, the output pressure can be automatically controlled at the set output pressure through the frequency conversion pump. Thereby, the power consumption of a pump can be reduced. Depending on the flow rate, bypass piping may be required
Circulation heating is possible without a heater because it is heated by the exhausted heat
Verwandte Empfehlungen
-
Storage tank cooling refrigeration chiller
1772Tank cooling chiller is a device specifically used to cool materials in a tank to ensure that the materials in the tank are stored within a suitable temperature range to maintain the quality and performance of the materials. This type of chiller i...
Details anzeigen -
Kühl- und Heizsystem der Hydraulikanlage mit Temperaturregelung
1548Die Anwendung von Kühl- und Heizungs-Temperaturkontrollsystemen in Hydrauliksystemen ist sehr wichtig, vor allem wenn eine präzise Temperaturkontrolle erforderlich ist. Dieses System kann sicherstellen, dass das Hydrauliköl innerhalb der...
Details anzeigen -
FLTZ Mehrkanalige Serie
4283Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates continuously for 24 hours Mainly used for precise temperature control in semiconductor production and testing processes, heating within ...
Details anzeigen -
Erfordert der Chip Lead Bonding-Prozess ein Temperaturkontrollsystem?
1752Der Chip Lead Bonding-Prozess erfordert in der Tat eine präzise Temperaturkontrolle. Daher sind Temperaturkontrollsysteme in der Regel so ausgestattet, dass sie Prozessstabilität und Ausbeute gewährleisten. Im Folgenden werden die Bedeutung und die Anwendungsszenarien der Temperaturkon...
Details anzeigen
工業冷水機製造商 LNEYA Taiwan