Precautions for chiller cooling system in low temperature operation test
There are certain differences in the use method, function, structure, etc. of different types of chiller cooling systems for low-temperature operation test.
The chiller of the industrial low-temperature operation test requires heat to be generated during operation. The cooling air should be circulated. There should be a certain space around the installation, and the generated heat should be dissipated upwards, so do not install it around equipment that is not heat-resistant. The chiller of the industrial low-temperature operation test cooling system should be installed directly on the horizontal surface. Do not install it upside down, diagonally or vertically.
The chiller cooling system for industrial low-temperature operation test cannot be installed in places where there are various fibers, paper (chips), metal fragments, etc. The water outlet of the chiller cooling system for industrial low-temperature operation test should be connected with the water inlet of your instrument, and the water outlet of the instrument should be connected with the water inlet of the cooling circulating water machine.
Check whether the air filter, heat exchanger coils and fins of the air-cooled low-temperature operation test cooling system chiller are too dusty. Is the air inlet and outlet dredged? Is the fan and fan blade working normally? Is the wind power normal? Is the water system normal?
Check if the chiller water system of the air-cooled low-temperature operation test cooling system is leaking. Is the water inlet and outlet dredged? Is the pump working normally? Listen to the power on and listen to the air-cooled low-temperature operation test cooling system chiller compressor working sound is normal, whether there is abnormal sound, whether the electric fan, water pump is noisy, whether the noise is too loud, etc. The chiller of the air-cooled low-temperature operation test cooling system is in operation, and under normal conditions, the oscillation is slight and the noise is small.
Check the air-cooled low-temperature operation test cooling system chiller refrigeration system for cracks, damage, frost and condensation and other conditions in the pipes. Whether there is friction between the chiller refrigeration pipes of the air-cooled low-temperature operation test cooling system, the pipes and the shell, etc., especially the welding place of the refrigerant pipe, and whether there is the connection of the chiller joint of the air-cooled low-temperature operation test cooling system Leakage, as long as there is a leak, there will be oil stains. You can also use a clean soft cloth or soft paper to scrub the welded joints and joints of the pipeline, and investigate whether there is any oil stains to determine whether there is a leak.
Check whether the electrical system fuse of the air-cooled low-temperature operation test cooling system chiller is blown, whether the insulation of the electrical wire is intact, whether the circuit board is cracked, whether the connection is loose, etc. Especially if the electrical connection is excellent in touch, the wiring screws and connectors are easy to loose and cause poor touch.
관련 추천
-
선형 급격한 온도 변화 테스터 비우기 및 채우기 지침
2128선형 급격한 온도 변화 테스터를 시작하기 전에 화재 방지, 보호, 누출 방지 및 기타 도구와 같은 관련 보호 조치가 마련되어 있는지 확인하십시오. 전원 공급 장치가 제자리에 있는지 확인 ...
세부 정보 보기 -
Cautions for Ultra-low Temperature Freezer
19581. Requirements of equipment environment: To keep the outside of cryogenic refrigerator clean and ventilated, it is necessary to keep the horizontal position of cryogenic refrigerator stable, and to ensure that there are no sundries around. 2. Man...
세부 정보 보기 -
신에너지 차량 품질 테스트를 위한 KRY 시리즈 수냉식 냉각기
1872새로운 에너지 차량 파워트레인 테스트 벤치는 하프샤프트를 통해 전기 구동 어셈블리의 동력 출력단에 직접 연결할 수 있습니다. 프런트 엔드에는 고정밀 토크 센서와 속도 센서가 장착되어있어 높은 정밀도를 제공합니다.
세부 정보 보기 -
'NCP'에 맞서 싸우며 안전하게 생산을 재개하는 LNEYA
24072020년 새해가 안개를 드리우고 있지만, 모든 것이 회복되는 순간은 결코 오지 않을 것입니다. 현재 전국의 많은 기업에서 운영 부담과 어깨에 짊어진 책임이 매우 무겁습니다. 그러나 LNEYA는 ...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan