How to Choose Water Chiller Units in Small Factories
Professional water chiller factory said that the quality of equipment can be seen from the three main components of small water chiller units. The most important one is the compressor, which is the heart of the unit and the most critical component. A good compressor should not only run stably, but also ensure good energy efficiency.
Evaporator and condenser are also one of the main components of water chiller. Evaporator and condenser play the role of heat absorption and exothermic respectively. Adequate and appropriate heat transfer can give full play to the efficiency of compressor. If the heat transfer capacity of the condenser is insufficient, it will directly affect the refrigeration effect of the unit. In summer, the high pressure is easy to occur, and even the protection shutdown of the chiller is caused by the high pressure exceeding the standard. The heat transfer of evaporator is more important. The insufficient heat transfer will not only cause the inefficiency of the unit, but also make the refrigerant unable to evaporate completely. It will directly return to the compressor to cause liquid hammer and damage the compressor, thus making the whole chiller unusable.
Another main component is the expansion valve, which is not only a flow regulating valve but also a throttle valve in refrigeration equipment in the refrigeration system of water cooler. The main function is to reduce the pressure and throttle the refrigerant liquid flowing through the thermodynamic expansion valve at high pressure and normal temperature, and to change it into low temperature and low pressure refrigerant wet vapor, which enters the evaporator and vaporizes and absorbs heat in the evaporator, so as to achieve the purpose of refrigeration and cooling.
Small factories should pay attention to the following three points when choosing and purchasing:
1. Selection of key parts for chillers.
Compressor is the main index affecting the performance of shadow water chiller. In order to control the overall production cost, many water chiller manufacturers adopt poor quality products in compressor and other major parts, and even use retrofitted compressors, which seriously affects the later use efficiency of industrial water chillers, resulting in increasing energy consumption.
2. Controlling the purchase cost.
On the premise of guaranteeing chiller’s main energy, it can achieve the goal of reducing cost and satisfying enterprise’s production demand with the least capital by purchasing industrial chiller products at a higher cost performance ratio.
3. Purchase chillers according to the environment used by enterprises.
Water quality and air quality have a certain impact on the operation of water chillers. It is necessary to inform the water quality and air quality of the position of the water chiller manufacturer’s own enterprise in advance.
관련 추천
-
Model and size selection of cooling and heating circulator (pilot plant temperature control system)
2046The cooling and heating circulator adopts mechanical refrigeration, the low-temperature heating tube heats the high temperature, and the canned pump is used as the circulating pump. The liquid circulation of the whole system is closed and consists...
세부 정보 보기 -
Changes in temperature control methods during semiconductor testing
2130As the use of semiconductor devices expands into new areas, such as automotive electronics, stricter requirements are imposed on their performance. Example: Devices are now required to operate at very low temperatures (about -40°C). To determine w...
세부 정보 보기 -
화학 합성 공정 제어 시스템 온도 제어 시스템 TCU
2137오늘은 DCS 통합 제어 시스템(합성 공정의 온도 및 기타 제어)에 대해 이야기해 보겠습니다. 확장성: 이 시스템은 개방형 시스템으로 표준 TCP/P 데이터 통신 인터페이스 프로토콜, 인터페이스 소프트웨어 및 ...
세부 정보 보기 -
플래시 고온 및 저온 테스트 냉각기의 주요 유지보수 포인트
1936플래시 고온 및 저온 테스트 냉각기 구매자가 날로 증가하고 있습니다. 많은 사람들이 구매 후 서비스 수명이 크게 줄어든다는 것을 알게됩니다. 따라서 운영 관리 및 유지 보수 담당자는 특정 전문 지식이 있어야합니다.
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan