저온 사이클 장비 작동의 중요성 설명
저온 사이클 장비의 사용은 표준 작동과 분리할 수 없습니다. LNEYA 저온 사이클 장비는 해당 사용 설명서와 함께 배송되며 사용자는 사용시 미리 알 수 있습니다. 저온 ...
The low temperature circulation equipment, also known as the low temperature constant temperature bath, is a high precision constant temperature source with its own refrigeration, and has the function of a small chiller. Widely used in petroleum, chemical, metallurgy, pharmaceutical, biochemical, physical properties, testing and chemical analysis and other research departments, institutions of higher learning, factory laboratories and metrological quality inspection departments. According to the different opening size of the low-temperature cycle equipment, the constant temperature experiment can be carried out in the equipment, or it can be connected with other equipment through the hose and used together with the constant temperature source.
Low temperature cycle equipment should be used when the medium is used. When the working temperature of the medium in the equipment is relatively low, an aqueous solution of ethylene glycol or absolute ethanol is generally used. When the working temperature is 5 ° C to 80 ° C, deionized water is generally used. When the operating temperature of the low temperature cycle equipment is 80 ° C to 98 ° C, a 15% glycerin aqueous solution is generally used.
Low-temperature cycle equipment uses working power: 220V/50Hz, the power supply should be greater than the total power of the instrument, the power supply must have a good “grounding” device, use liquid medium in the low-temperature cycle equipment, the liquid level of the medium should be lower than the working table 30mm, Otherwise, the heater will be damaged when the power is turned on. When the temperature is higher than room temperature, please turn off the cooling, and the temperature inside the device can be completely controlled. Do not use ethanol when the temperature of the low-temperature cycle equipment is higher than 30 °C, so as to avoid danger. (Because of the high rate of volatilization at high temperatures, it is prone to danger).
The low-temperature circulation equipment should be placed in a dry and ventilated place, and there is no obstacle in the 300mm around the instrument. When the working temperature of the equipment is high, care should be taken not to open the upper cover, and do not enter the tank to prevent burns. After use, all the switches are turned off, the power is cut off; the cleaning work is done, and the work surface and the operation panel are kept clean.
Different manufacturers may have slightly different differences, so users need to know about the low-temperature cycle equipment they purchased. If you are not sure, you can contact the relevant manufacturers to obtain relevant information.
관련 추천
-
저온 순환 장치의 프로스팅을 해결하는 방법은 무엇입니까?
2473저온 순환 장치 프로스팅의 고장은 주로 압축기 복귀 공기 온도가 너무 낮기 때문에 스로틀 밸브 액체 냉매 공급이 저온 순환 장치에서 정상 상태 일 수 있습니다 ...
세부 정보 보기 -
What is the temperature control of the reactor?
2272The reactor cooling system is one of the common equipment in the chemical industry. It can not only heat but also refrigerate to meet the needs of heating and cooling in the reaction process. There are usually three ways to control the temperatu...
세부 정보 보기 -
Explosion-proof cryogenic refrigeration unit icing, do you know what is going on?
2460When using an explosion-proof cryogenic refrigeration unit, many users do not know how to solve the problem of icing and frosting. In fact, the professional can tell you with certainty, no. The two causes are different, so the processing method is...
세부 정보 보기 -
금속 부품 및 업계의 일반적인 조립 방법을 위한 냉각 및 수축 조립 냉동고
2980구리 슬리브, 베어링 등의 냉간 수축 생산에서 급속 냉동 극저온 상자는 기계 조립에 널리 사용됩니다. 구리 슬리브 냉각 수축 조립 캐비닛 가변 온도 조립 방법은 구멍을 가열하거나 냉각하는 것입니다 ...