Refrigeration control system compressor failure caused by oil pressure
If there is no oil pressure in the refrigeration control system, check the oil pump piping system connection for oil leakage or blockage. If the connection is loose, the joint should be tightened. If it is blocked, the oil pipeline should be cleared. Then check whether the compressor of the refrigeration control system is too large due to the opening of the oil pressure regulating valve or the valve core is detached. If the hydraulic pressure regulating valve of the refrigeration control system is improperly adjusted, adjust the oil pressure regulating valve and adjust the oil pressure to the required value. If the valve core is detached, the valve core should be reinstalled and tightened. If there is too little oil in the crankcase of the refrigeration control system or there is refrigerant, the oil pump will not enter the oil. If the oil is too small, it should be timely. Refueling, if it is the latter, stop in time to eliminate the refrigerant. Pay attention to the oil pump. If the oil pump wears out seriously, the clearance will be too large, causing the oil pressure to not come up. In this case, the oil pump should be repaired and replaced directly if the fault is serious. The timely cooling control system checks whether the connecting rod bearing bush, the main bearing bush, the connecting rod small head bushing and the piston pin have been seriously worn, and the relevant parts are replaced in time, and the rear end cover gasket of the crankcase is misplaced, blocking the intake of the oil pump. The oil passage should be disassembled and the position of the gasket should be re-fixed.
Of course, the oil temperature of the refrigeration control system needs to be in the normal range. If the oil temperature is too high, it is necessary to check in time whether the shaft and the tile are improperly assembled, and the clearance is too small. The size of the shaft and tile assembly clearance should be adjusted so that the clearance meets the standard requirements. It is. Next, check the lubricating oil for impurities, which will cause the bearing bush to be pulled. For this, the brushed bushing should be flattened and replaced with new oil. If the tile is severely pulled, replace the new tile. Then check that the shaft seal friction ring is installed too tightly or the friction ring is pulled, and the shaft seal friction ring is re-adjusted in time. If the friction ring is severely pulled, replace the new friction ring. If the suction and exhaust temperatures of the compressor of the refrigeration control system are too high, the system’s liquid supply valve should be properly adjusted to restore the suction and exhaust temperatures to normal.
Overall, the refrigeration control system compressor failure solution is not as simple as imagined, so we need our operators to know more about our refrigeration control system and have enough knowledge to face these faults.
관련 추천
-
Working state of temperature control circulating device for purification of small-scale distillation
1841Distillation reflux concentration and purification temperature-control circulating device is widely used in many fields. It is very important to select appropriate equipment, which can greatly improve product quality and reduce production costs t...
세부 정보 보기 -
플래시 고온 및 저온 테스트 냉각기의 주요 유지보수 포인트
1936플래시 고온 및 저온 테스트 냉각기 구매자가 날로 증가하고 있습니다. 많은 사람들이 구매 후 서비스 수명이 크게 줄어든다는 것을 알게됩니다. 따라서 운영 관리 및 유지 보수 담당자는 특정 전문 지식이 있어야합니다.
세부 정보 보기 -
Cooling method for semiconductor testing chiller to meet temperature control requirements
2494The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to stabilize chemical reactions; the electronic manufact...
세부 정보 보기 -
극저온 냉장고의 크라이오 펌프 설치 지점
2311극저온 냉장고의 건설에서 크라이오 펌프는 필수입니다. 저온 냉동고 제조업체 인 LNEYA는 크라이오 펌프가 설치 될 때 요구 사항에 따라 작동해야한다고 모든 사람에게 알려줍니다. 설치 시설 ...
세부 정보 보기
工業冷水機製造商 LNEYA Taiwan