Characteristics and Advantages of Air Cooled Chillers
1. Configuration of air-cooled chiller
Air cooled chillers can be divided into air-cooled vortex chillers and air-cooled screw chillers according to the type of compressor. The air-cooled vortex chiller is mainly composed of vortex compressor, evaporator, condenser, refrigeration element, circulating water pump, stainless steel water tank and original imported fan electric control system. The air-cooled screw chiller is composed of screw compressor, evaporator, condenser, refrigeration components, imported fan and electric control system. All the above parts are guaranteed to be 100% new and original. Welcome new and old customers to our factory for on-site inspection.
2. Protective device of air-cooled chiller
Long service time or improper operation of air-cooled chiller will cause unit failure. In order to ensure the safe and stable operation of chiller, the equipment itself is equipped with multiple safety protection devices, such as reverse phase protection device, compressor overload protection device, high and low pressure protection device, automatic alarm device, low temperature anti icing protection device, etc. Even if the chiller fails, the protection device can be started at the first time to avoid secondary injury to the chiller.
3. Temperature control of air-cooled chiller
Both air-cooled box chillers and air-cooled stacked rod chillers can meet the refrigeration temperature required by various industries, up to 350 ℃ and down to – 150 ℃. Moreover, the temperature adjustment can be set on the control panel of the chiller according to the demand. The specific setting method can be in accordance with the operation manual of the chiller.
4. Energy saving and environmental protection of air-cooled chiller
Chillers belong to mechanical equipment, and the primary problem considered by users is power consumption. One feature of air-cooled chiller is that after reaching the refrigeration temperature required by users, the compressor stops running to save electric energy. When the temperature is higher than the temperature set by the user, the compressor will restart to save power consumption for the user to a certain extent. In addition, for chillers with multiple compressors, each compressor has an independent refrigeration system. Users can decide the number of compressors to be started according to production needs, which is more flexible and convenient to use.
Related recommendations
-
Fault Hint of Cryogenic Chiller Refrigeration System
1766When the high and low pressure of the system are higher than normal, there is usually air or excessive refrigerant in the system. At this time, we need to re-vacuum, and then add a proper amount of refrigerant to solve this problem. But there are ...
View details -
Electric Vehicle Motor Test Cooling System Chiller Instructions
2525With the continuous development of new energy vehicles, Chiller, the electric motor motor test cooling system, is also developing. The new chiller for motor testing of new energy vehicles can adaptively adjust the chiller according to the dynamic ...
View details -
Attention points for daily inspection of low temperature control equipment at minus 30℃
1901The low temperature control equipment at minus 30 degrees Celsius is a refrigeration unit or also called a refrigeration unit. The difference from the chiller is the temperature range. It is a commonly used low-temperature equipment in the industr...
View details -
Shutdown method in the case of high-precision high-low temperature circulator failure
2213The high-precision high-low temperature circulator is one of the equipments used in the pharmaceutical and chemical industry to support various reactors. If users encounter an abnormal power outage during use, they should pay attention to operatio...
View details
工業冷水機製造商 LNEYA Taiwan











