Principle Analysis of Glycol Chiller

Glycol chiller is an industrial chiller
with glycol as refrigerant. The structure of glycol chiller is roughly the same
as that of ordinary industrial chiller, which is composed of compressor,
evaporator, condenser and electric control system. In order to ensure the
stable operation of glycol chiller, we suggest that you take explosion-proof
measures and buy explosion-proof glycol chiller as far as possible.
1、 Operation of compressor
In order to ensure that the pressure inside
the evaporator is low enough and that the refrigerant is at such a low
temperature, the compressor is used to extract the evaporated refrigerant and
compress the low temperature and low pressure into high temperature and high
pressure refrigerant gas.
2、 Use of condenser
High temperature and high pressure
refrigerant condenses into liquid in the condenser. The refrigerant in the
condenser releases heat in air or water lower than its temperature. Of course,
the temperature of air or water must be lower than that of refrigerant.
3、 How to throttle
After passing through the restrictor, the
refrigerant of the chiller drops from the condensation pressure to the
evaporation pressure, so the liquid from the condenser can be placed in the
liquid reservoir. At this time, the refrigerant is in the state of normal
temperature and high pressure, and then passes through the expansion valve to
reduce the boiling point, enters the evaporator, and the liquid absorbs heat
and evaporates.
4、 Endothermic evaporation
After passing through the restrictor, the
refrigerant liquid with low temperature and low pressure exchanges with the
evaporator, and the absorbed heat becomes saturated or superheated steam.
Related recommendations
-
What are the influences on the refrigeration factors of the enclosed explosion-proof chiller?
1982Check if it is the cause of the failure of the enclosed explosion-proof chiller. This selection must be accurate. If the model is not in place, the required cooling effect will not be achieved. It is recommended that the user will need it when pur...
View details -
The Role of Chemical Refrigeration Temperature Control Unit
1988In pharmaceutical and chemical plants, the raw materials inside the reactors involved in industrial production require rapid cooling and cooling. In order to achieve this goal, the reactor undergoes direct refrigeration and cooling, thereby indi...
View details -
High-pressure failure of stainless steel cryogenic refrigerator
2396At the high speed of the stainless steel cryogenic refrigerator compressor, the temperature rises and the compressor generates high air pressure, which causes the high voltage protection relay to operate. The discharge pressure of the compressor r...
View details -
The difference between direct contact liquid cooling and cold plate liquid cooling technology
2350The cold plate liquid cooling technology is an implementation method in which the heat of the heating components is indirectly transferred to the cooling liquid enclosed in the circulating pipeline through the cold plate, and the heat is taken awa...
View details
工業冷水機製造商 LNEYA Taiwan