Industry and introduction of low temperature chiller
In petroleum refining, petrochemical industry, organic synthesis, chemical products and other industrial production, refrigeration technology must be applied to control the reaction temperature during processes such as liquefaction, condensation, solidification, separation, refining, crystallization, concentration, and purification.
The chemical industry is mainly used for the cooling and cooling of chemical reaction kettles, and takes away the ordinary heat generated by chemical reactions in time to reach the purpose of cooling (cooling), in order to improve product quality. If the cold water (wind) provided by the refrigerator is used for cooling, not only the product quality can be greatly improved, but also the consumption efficiency can be improved. The pharmaceutical industry is mainly used to control the temperature and humidity of the workshop and to take out the heat of reaction during the process of consuming the drug substance.
Refrigerators in the industry are basically composed of components such as evaporators, single-stage compressors, oil separators, condensers, and liquid storage tanks. LNEYA’s freezer has exclusive technology, the temperature range is -5 ℃ ~ -150 ℃, which can meet different temperatures. This cooler uses international brand Carrier compressor, adopts automatic cascade refrigeration mode and mixed refrigerant, direct cooling ultra-low temperature freezer, single compressor automatic cascade refrigeration technology can freeze to minus 120 ° C in 3 minutes. Before delivery to customers, the production workshop provides machine installation and system testing. Users only need to complete the installation of refrigerant and cooling water.
The working principle of LNEYA low temperature chiller is as follows:
low temgperature chiller appearance:
Related recommendations
-
What Are The Characteristics Of Refrigeration Of Industrial Chillers?
2124If there is a high temperature difference between the inlet and outlet water, then a large external tank will be used to store cold water. In this case, the cooling water will not be directly from the cooler application. Deep into the outside of t...
View details -
Protection device details of circulating fluid temperature control device
2188The circulating pump overload protection function is to cut off the main power of the circulating pump when the circulating liquid temperature adjustment device is too large. Press the green button when resetting; the red button is the stop button...
View details -
The advantages of water cooled chiller you need to know
1911Industrial chillers can be generally divided into water-cooled and air-cooled according to the type of refrigeration. The heat exchange medium of Water Cooled Chillers is water.LNEYA has designed and developed a new type of temperature control equ...
View details -
What do you need to consider for a car battery cooling water cycle heat exchanger?
1828The car battery cooling water circulation machine has always been one of the most popular equipments. The design of the heat exchanger piping also needs to be designed. What aspects should be considered? There are many types of heat exchange equip...
View details