What causes sediment in the use of the chiller cooler?
A chiller is a water-cooled unit that uses water circulation to provide a constant temperature, constant flow and constant pressure cooling water. The LNEYA cold water system has its own working principle, that is, a certain amount of water is injected into the water tank of the machine, the cooling water is cooled by the refrigeration system, and then the cooling water is operated by the compressor. The cooling water is sent to the equipment to be cooled, the heat is taken away, then the temperature rises, and then flows back to the water tank to achieve a cooling effect. However, when using a chiller for a long time, there will usually be some dirt deposits in the chiller pipe or water tank. What is the reason below.
1.Chemical processor
If a zinc salt or a phosphate inhibitor is added to the water circulation system, zinc or phosphate scale is formed. Therefore, we must always carry out maintenance work on the chiller, not only to ensure the cooling capacity, but also to extend the service life of the chiller.
2. Process media leakage
The water cooler leaks, especially if it leaks oil or some organic matter causes deposits to form.
3. Air
Sediments, dust, microorganisms and their spores enter the circulatory system with the air, and sometimes insects are carried into the system, causing the heat exchanger to clog. When the environment surrounding the cooling tower is contaminated, corrosive gases such as hydrogen sulfide, chlorine dioxide and ammonia will react in the unit and indirectly cause deposition.
The LNEYA chiller cooler is a fully enclosed system that does not expose the media to outside air during use.
It can be seen from the above that in the use, the chiller needs to be maintained at all times, which not only ensures the cooling capacity, but also prolongs the service life of the chiller and the saving of circulating water.
If you need any information, you can contact LNEYA to inquire about the use of chiller coolers and other cooling system equipment at sales@lneya.com/LNEYA.COM.
Related recommendations
-
Linear rapid temperature change tester emptying and filling instructions
2128Before starting the linear rapid temperature change tester, check whether the relevant protective measures are in place, such as fire protection, protection, leak prevention and other tools. Check whether the power supply is in place according to ...
View details -
What should I pay attention to when replacing a water-cooled chiller compressor
1942Once the compressor of the water-cooled chiller fails, the compressor needs to be replaced in time, but the replacement of the compressor is not as simple as imagined. Before the water-cooled chiller compressor is replaced, the reasons for the da...
View details -
Various reactors and materials use PLC temperature control system
2253The PLC temperature control system is used for the lifting and constant temperature control of glass reactors, metal reactors and bioreactors, especially for heat exothermic control in the reaction process. The heat transfer oil in the jacket of t...
View details -
Low temperature chilled lubricant selection considerations
2406When you use a cryogenic chilled, you definitely want to know about all aspects of the cryocooler. But one of the things that needs everyone's attention is that the type of lubricant for the chilled is chosen because there are many influencing fac...
View details
工業冷水機製造商 LNEYA Taiwan