What are the functions of the controllers for semiconductor temperature control equipment?
In the temperature control equipment of semiconductor components, each accessory has a different function. Due to the different functions, the function of the temperature control valve and controller of the semiconductor components of LNEYA is different.
The temperature-controlled water pump of the semiconductor component is a tool for accelerating the flow of water to enhance the heat transfer effect of the water in the heat exchanger. The water flow switch of the semiconductor temperature control device is used for the control or interruption protection of the fluid flow in the pipeline. When the fluid flow reaches the set value, the switch automatically cuts off (or turns on) the circuit. The pressure controller is used for pressure control and pressure protection. The unit has low pressure and high pressure controllers to control the working range of the system’s pressure. When the system pressure reaches the set value, the switch automatically cuts off (or turns on) the circuit.
The differential pressure controller of the semiconductor temperature control device is used as a pressure difference control, and when the pressure difference reaches the set value, the switch automatically cuts off (or turns on) the circuit. The temperature controller is used for control or protection of the unit. When the temperature reaches the set value, the switch automatically cuts off (or turns on) the circuit. In our products, temperature control is often used to control the unit’s start and stop conditions. Some still require a temperature controller like antifreeze.
The semiconductor temperature control device is used to indicate the condition of the refrigerant in the liquid line in the refrigeration device, the water content in the refrigerant, the flow condition of the lubricating oil from the oil separator in the return line, and some sight glass belts. There is an indicator that indicates the water content in the refrigerant by changing its color. (green means dry and yellow means wet). The volume change of water caused by temperature changes, the expansion tank is used to store this part of the expansion water, the system is regulated and fixed, and the system can compensate part of the water.
The semiconductor temperature control device is a relatively new device, and the performance above is required to be higher to be more stable.
Related recommendations
-
Detailed Introduction of Air Cooled Chiller Equipment
1954LNEYA refrigeration has accumulated over 10 years of cooling supporting application experience. According to different application fields and service conditions, it has developed a variety of types of cooling chillers, including air cooled chiller...
View details -
How to judge the operating status of the chemical and pharmaceutical constant temperature control sy
1902Nowadays, many pharmaceutical and chemical industries use LNEYA's constant temperature control system. How to judge its operation status during operation? There should be no noise in the cylinder of the chemical and pharmaceutical thermostatic con...
View details -
Characteristics of the evaporator of LNEYA screw chiller
2764The amount of cooling capacity of the screw chiller is directly related to the energy consumption and operational economics of the entire unit, which is worthy of attention. Especially when designing a cold station, there is no single chiller in t...
View details -
Semiconductor refrigeration temperature control system accessories
2124In the evaporator, since the liquid evaporates in the evaporator of the semiconductor refrigeration temperature control system, the process from liquid to gas, due to the change of the load, some of the refrigerant may not be completely evaporated...
View details
工業冷水機製造商 LNEYA Taiwan











