What should you pay attention to when using the cooling and heating oil bath?
In the high and low temperature control, cooling and heating oil bath is one of the more important equipment. What aspects do users need to pay attention to when running the device?
The cooling and heating oil bath equipment should be kept clean and dry. It is strictly forbidden to heat the solution in the stainless steel pot without burning the heater to avoid burning the heater. If the measured temperature differs greatly from the actual temperature, it is usually obtained with the wrong sensor. Place the sensor in boiling water and the meter should display 100 °C. Otherwise check that the sensor is consistent with the meter input type.
The cooling and heating oil bath meter indicates that the HHH is the measured value that is outside the meter range or the thermocouple is broken. It indicates that the LLL is the measured value lower than the lower limit of the meter range or the thermocouple is reversed. The instrument of the cooling and heating oil bath shows normal, the temperature suddenly loses control, and the external load should be checked for short circuit or open circuit.
When the cooling and heating oil bath is not working, the power should be cut off. To ensure safety, please connect the ground wire during use. The electric power and the heat taken away from the load by the refrigerant need to be removed from the radiator at the front hood. The front hood is filled with dust and cotton wool, which will prevent the heat from being dissipated and the cooling effect will be greatly reduced. Generally, the decrease in cooling capacity under normal use conditions is caused by poor ventilation or high ambient temperature.
When the cooling and heating oil bath is in operation, it is necessary to understand these points of use and then operate better.
Related recommendations
-
60P ultra-low temperature water chiller consumes too much energy and needs attention
174460p ultra-low temperature water chillers of different manufacturers have different performance configurations and different energy consumption. If you find that the energy consumption is too large, you must check in time to see if there is a probl...
View details -
Small environmental test chamber compressor should pay attention after maintenance
2001In the centrifugal small-scale environmental test chamber, the suction recovery device is generally an independent system, and if necessary, the pipeline connected to the condenser and the evaporator can be closed for separate maintenance. After r...
View details -
What are the reasons for the power consumption of large-size refrigeration units?
1886During the operation of large-size refrigeration units, the cooling capacity and working conditions are the main issues of power consumption, but in order to avoid some unnecessary power consumption, we need to understand clearly. When the scale o...
View details -
How to complete the temperature control equipment for the isolation reactor?
1978The reactor is a commonly used reactor in pharmaceutical and chemical production. The isolation reactor temperature control equipment is realized by controlling two doors, namely the heating water valve and the cooling water valve. The mixing of t...
View details