Tips for Leakage Detection of Low Temperature Freezer
Soaking leakage detection
The sensibility of soaking leakage detection is higher than bubble test,which is usually applied for small Freon freezer unit. When using it, the equipment prohibited from contacting water in the system should be discharged, like all kinds of relays and electrical control device. Taking advantage of warm water during the bubble test, because its surface tension is smaller than cold water, forming bubbles more easily. As an editor of Low Temperature Freezer, I want to tell you that the leakage point will be discovered simply if accompanied by intense light source. After the completion of soaking leakage detection, the surface ought to be dried with compressed air, preventing the metal from corrosion.
Halide torch and its leakage detection
These are the specialized devices for detecting the Freon freezer unit system. When Freon refrigerating fluid encounters hot cooper parts, different colored flames will be casted for F2, C12 and Br contain the elements of halogen, helping find out the leaking point.
Vacuum leak test
When freezer unit system passes the pressure leakage detection, it should also go through the vacuum leak test since some pasts exist one-way leaker. Only pressure and vacuum leakage detection both conform to the standard can the leakproofness of cooling system can be ensured. Besides, the system is evacuated, so can water at the same time , esped dcially the Freon system. Therefore, evacuation and desiccation play essential roles in debugging the unit.
Should the uses for low temperature freezer be understood, the users will have a better try! Visit LNEYA to know more about low temperature freezer price.
Related recommendations
-
Temperature control mode of automatic control system of reaction kettle
1990The automatic control system of LNEYA reactor is the equipment used for temperature control of the reaction kettle. What are the temperature control methods of the automatic control system of the reactor? How are you controlling the temperature? T...
View details -
Maintenance of Top 10 Industrial Freezers
2161When we choose and buy industrial freezers of top 10 brands, in addition to some necessary needs, we should also pay attention to the use and maintenance of the industrial freezer, we should select industrial freezers with long service life, high ...
View details -
How to replace the four-way valve of industrial refrigeration equipment?
1650The four-way valve of industrial refrigeration equipment needs to be replaced in time after a long period of use, so how to replace it? When replacing industrial refrigeration equipment, you need to first remove the connecting pipe connecting the ...
View details -
Advantages of Cold Plate Freezer
1886The freezing method is mainly used when the capacitive liquid crystal touch panel of smartphones and tablet computers has defects in production, such as bubbles, foreign objects, black spots, white spots, misplaced..., and needs to be used for rew...
View details
工業冷水機製造商 LNEYA Taiwan