Main points of maintenance of flash high and low temperature test chiller
Buyers of flash high and low temperature test chiller are increasing day by day. Many people find that the service life is greatly reduced after purchasing. Therefore, operation management and maintenance personnel must have certain professional knowledge and professional skills, so that the service life will be longer.
If the flash high and low temperature test chiller system is properly maintained, it can improve use efficiency, reduce failures, extend the service life of the unit, and greatly reduce operating costs.
1. Regularly clean the air filter of the equipment:
is usually cleaned once every 2 to 3 weeks. Pull out the filter when cleaning, and use a dry soft brush to remove the dust on the filter. It can also be cleaned with water to remove the dust on the filter. After drying, put it into equipment for use.
2. Check the equipment plug and socket:
The user should always check whether the electrical plug of the equipment is in good contact with the socket. If it is found that the power lead or plug is hot when the flash flash high and low temperature test chiller is running, the reason may be that the electrical wiring is too thin or the plug or socket If it is caused by poor contact, measures should be taken to solve it.
3. Long downtime:
Flash Flash high and low temperature test When the chiller needs to be shut down for a long time (such as the seasonal shutdown of the equipment), the equipment should be cleaned.
4. Frequently clean the dust on the panel and cabinet:
Under normal circumstances, we use a dry cloth to wipe. Wipe first, and then wipe off the detergent with a cloth dampened with clean water. Do not use hot water, gasoline, volatile oil and corrosive solvents to clean the panel and casing of the equipment. Avoid using hard-bristled brushes to clean the equipment, so as not to damage the shell, causing paint peeling, fading, etc.
5. Regularly clean the condenser and evaporator coils of the flash high and low temperature test chiller:
Brush and vacuum cleaner can be used. Remind you that when cleaning, the brush and vacuum cleaner should be cleaned in the vertical direction of the coil, and do not clean in the horizontal direction, so as not to damage the fins of the coil.
Related recommendations
-
Introduction and advantages of cryogenic refrigeration system
2255The medium-sized single-fluid cryogenic refrigerator produced by our company has a cooling temperature range from -150℃ to -5℃, fast cooling speed, safe and reliable, used for rapid liquid cooling, applied to high-tech such as biochemical, freeze-...
View details -
The reason why the cooling water circulator needs the main water circulation
2302The supplement of the water cycle is directed to a water-cooled cooling water circulator, and the air-cooled cooling water circulator does not have this problem. The water-cooled cooling water circulator needs cooling water during normal operation...
View details -
Basic structure manual of industrial chiller
2217Industrial chillers are composed of compressors, condensers, evaporators, expansion valves and other accessories. 1. Compressor: In the industrial chiller system, the compressor is the power to ensure refrigeration. The compressor is used to incre...
View details -
Is it right to extend battery life by lowering the ambient temperature?
1872The battery can work in a wide temperature range, but this does not allow the battery to be charged under high temperature conditions. The charging process is more delicate than the discharging process, and extreme care must be taken. Extreme cold...
View details
工業冷水機製造商 LNEYA Taiwan