Choosing a water chiller is like finding a “target” for an enterprise’s production equipment. It must not only be “like-minded”, but also “be well-matched”. The one that suits you is the best. If the choice is not good, either the cooling effect is not ideal, or energy is wasted, and other problems will appear.
First consider the actual situation of your own business, starting from six points:
1. The relationship between temperature difference and flow rate
How much material, how long does it take to cool down to how many degrees? In this way, the temperature difference of ice water required for cooling will be formed. The temperature difference of ice water is generally 3°C-5°C, but sometimes it may be 1°C-2°C. As far as the temperature difference is concerned, the smaller the temperature difference, the more ice water flow is needed to take away the same amount of heat, otherwise the less ice water flow is required.
2. Consider the solution with the least energy consumption
Energy consumption refers to electricity consumption. Especially when selecting a large industrial chiller, the comprehensive utilization and balance of electricity, heat and cold should be fully considered.
3. Refrigeration and stand-alone cooling capacity
The cooling capacity of the chiller is directly related to the energy consumption and operating economic effect of the whole unit, which is worth noting. For example, your production line requires stable and continuous refrigeration. Generally, there is no single chiller. When a chiller fails or is shut down for maintenance, other chillers are required to replace it. A reasonable number of units should be selected in combination with the production situation.
4. Are there any requirements for environmental protection?
There will be noise when the chiller is running, and the noise value will increase or decrease with the size of the chiller; some refrigerants used in chillers are toxic, pungent, flammable and explosive; some refrigerants will destroy the ozone layer in the atmosphere, When it reaches a certain level, it will pollute the air environment.
5. Cooling water quality requirements
The water quality of the cooling water will affect the cleanliness of the pipeline, especially the evaporator. Poor cooling water quality will accelerate the scaling and corrosion of the pipeline. This will not only affect the reduction of the cooling capacity of the industrial chiller, but also lead to replacement The heat pipe is clogged and damaged.
6. Explosion-proof and other special requirements
Chillers often work in harsh conditions and are often exposed to special substances such as flammable and explosive gases. When selecting a model, it is necessary to know whether the working environment of the chiller is an inflammable and explosive environment, whether it can be treated with explosion-proof treatment, and what is the explosion-proof level , and match the most suitable chiller scheme after comprehensive refrigeration demand.
The above are 6 considerations for choosing a chiller solution in the industry. You can also directly send the process temperature control requirements to sales@lneya.com. Our technical engineers will calculate the process parameters, determine the most suitable chiller model and send the equipment information and quotation to the customer.
Related recommendations
-
The reason why the semiconductor small thermostat is blocked by refrigeration
2149The small semiconductor small-scale thermostat ice jam is mainly caused by the excessive moisture contained in the refrigeration system. With the continuous circulation of the refrigerant, the moisture in the refrigeration system gradually collect...
View details -
Analytical description of accessories used in low temperature chiller
1642The low temperature chiller still uses a larger amount of cooling water equipment in our usual refrigeration equipment. When using it, you must first understand the principle of the low-temperature chiller and various accessories to better operate...
View details -
Common Faults of Salt Spray Environmental Chambers
1993The enterprise users are often at a loss when dealing with common faults in the salt spray environmental chamber. For this reason, Wuxi LNEYA, a manufacturer of the salt spray environmental chamber, specially reorganized the related common fault t...
View details -
[Invited to visit] CPHI CHINA 2019, Wuxi Guanya W5P22 booth is looking forward to your arrival!
2309On June 18-20, 2019, the 19th World Pharmaceutical Raw Materials China Exhibition - CPhI China 2019 will re-enter Shanghai New International Expo Center. CPhI China World Pharmaceutical Raw Materials China Exhibition is an international, high-qual...
View details
工業冷水機製造商 LNEYA Taiwan