Reasons for the decrease of heat transfer effect of vertical ultra-low temperature refrigerator
If the outer frost layer of the vertical ultra-low temperature refrigerator is too thick or excessively dusty, it can be caused because the external temperature of the evaporator is mostly lower than 0 °C, resulting in low heat transfer efficiency of the evaporator. Because the vertical ultra-low temperature refrigerator has relatively high humidity, the moisture in the air is easy to frost on the surface of the evaporator, and even freezes, which affects the heat transfer effect of the evaporator. In order to prevent the outer frost layer of the evaporator from being too thick, it needs to be timely Defrost.
There are two convenient defrosting methods: stop defrost, that is, stop the compressor operation, open the vertical ultra-low temperature refrigerator door, let the temperature rise, and then restart the compressor after the frost layer is automatically melted. Another is the cream. After the articles in the vertical ultra-low temperature refrigerator are carried out, the surface of the evaporator tube is directly washed with tap water having a relatively high temperature to dissolve or fall off the frost layer. In addition to the excessive frosting, the heat transfer effect of the evaporator is not good. The appearance of the evaporator is too thick due to temporary uncleaning, and the heat transfer efficiency is also significantly reduced.
Vertical ultra-low temperature refrigerators have poor heat insulation and heat preservation effects, which can also lead to poor heat transfer effect, poor heat insulation and heat preservation effect, and poor heat insulation performance because the thickness of the insulation layer of the pipeline is insufficient. Mainly due to the improper selection of the thickness of the insulation layer when designing the vertical ultra-low temperature refrigerator or the poor quality of the insulation data during construction. In the process of construction, the insulation moisture-proof function of the insulation data may be destroyed, resulting in moisture, deformation and even erosion of the insulation layer. The heat insulation capacity is reduced, and the loss of the anti-cooling capacity of the vertical ultra-low temperature refrigerator is increased, and the decrease is significantly slowed down.
Another important cause of large loss of cooling is the poor sealing performance, and more hot air invades the vertical ultra-low temperature freezer from the leak. Generally, if there is condensation on the seal of the refrigerator door or the seal of the cold storage wall, it means that the seal is not tight. In addition, frequent switching of the vertical ultra-low temperature refrigerator door or more people into the vertical ultra-low temperature refrigerator will also increase the cold storage loss of the warehouse. The vertical ultra-low temperature refrigerator door should be prevented from being opened as much as possible to prevent a large amount of hot air from entering.
These look to help the staff of the vertical ultra-low temperature refrigerators to work with friends, for detailed work conditions and maintenance instructions.
Related recommendations
-
What are the effects of the oil separator on the equipment analyzed by the chiller manufacturer
1805Oil separators use more accessories in the chiller refrigeration system. So as users, we need to understand where the main impact is in order to better use the equipment. In the configuration of the chiller, the position of the oil separator is ...
View details -
How to solve the problem of refrigeration pump circulator pump failure?
2081Cooling heating devices are required in many chemical pharmaceutical and laboratory applications. Then how to solve the failure of the refrigeration heating device is also concerned about how to solve it? 1. Circulating pump failure The circulatin...
View details -
The importance of car cooling water cycle maintenance
2210Even if the overall running quality of the car cooling water circulation machine is high, if there is no maintenance and maintenance in the specified time, the car cooling water circulation machine may have different degrees of failure. Especially...
View details -
Importance of refrigerants in new energy vehicle battery test systems
2397If the flow rate of the refrigerant in the new energy vehicle battery test system is extremely small, the refrigerant will start to expand from the first expandable space at the rear end of the throttle valve. Most of the see-up of the rear end of...
View details
工業冷水機製造商 LNEYA Taiwan