Ultraviolet etching machine water cooling unit chiller is a kind of refrigeration equipment widely used in industrial production. It can provide an effective cooling environment for different industrial productions, and it can provide great convenience for many industrial productions.
1. The use of the water cooling unit chiller of many UV etching machines requires a better understanding of basic knowledge such as product performance. For example, after the on-site installation of the chiller products equipped with UV etching machines, if no accidents are found in the appearance inspection If it is damaged, you can directly open the relevant valves (you should read the manufacturer’s instruction manual first. During transportation, the valves on the unit are generally closed) and start-up debugging. If it is found that the refrigerant has been leaked or insufficient, first find out the leak point and eliminate the leakage phenomenon, and then add the specified brand of refrigerant according to the requirements of the product instruction manual, and pay attention to the refrigerant charge should meet the technical requirements.
2. When using the chiller of the water cooling unit of the UV etching machine, special attention should be paid to the refrigerant of the chiller of the water cooling unit of the UV etching machine. In general, it is required to charge the refrigerant of the chiller equipped with the UV etching machine and the The refrigerant brand is in accordance with the regulations, and the refrigerant charge is insufficient, which will lead to insufficient cooling capacity.
3. In the selection of chiller for the water cooling unit of the UV etching machine, there are many operating temperatures that are not fixed, and the operation methods are also different. The temperature from the water outlet to the water inlet is different.
4. Users generally pay great attention to the maintenance of the chiller of the water cooling unit of the UV etching machine. Generally, they will regulate the start-up time, because it cannot be opened for a long time without interruption, which will cause great damage to the internal parts, and then affect the normal operation of the machine.
5. When operating the chiller of the water cooling unit of the UV etching machine, it is necessary to pay attention to the change of the internal temperature and keep it within the set range. Once the allowed temperature is exceeded, it is an abnormal situation. Exhaust faults.
6. After the water cooling unit chiller of the UV etching machine has been used for a period of time, its oil tank needs to be cleaned regularly, because moisture will be generated at the bottom of it, which will damage the cooling coil.
7. The oil in the chiller of the water cooling unit of the UV etching machine should also be kept clean, and its filter should also be cleaned and inspected regularly to prevent debris and dirt from remaining.
Related recommendations
-
The reason for the existence of cryogenic refrigerator in the tool parts manufacturing industry
1685Cryogenic treatment is applied to worn tools, die cutter materials, and later extended to alloy steel, cemented carbide, etc., this method can change the internal structure of metal materials, thereby improving the mechanical and processing proper...
View details -
Precautions for the use of molecular distillation cooling and heating temperature control
1839The SUNDI series of LNEYA refrigeration and heating temperature control system are used together to control the temperature in the process of molecular distillation. What should be paid attention to in use? If the molecular distillation method ca...
View details -
The Main Application Areas of Air Cooled Chillers
1835In the domestic and international industrial water chiller market, our most common industrial water chiller equipment can be roughly divided into two different types, one type is industrial air cooled chiller, the other type is industrial water co...
View details -
Analysis of the causes of noise generated by the operation of low temperature chillers
1891Noise is common in the operation of industrial equipment. There are many reasons for noise, which may be caused by some environmental problems in the installation. When noise is generated, we must first confirm the cause and whether it is an inter...
View details
工業冷水機製造商 LNEYA Taiwan