Memory chip test equipment system program description
With the rapid development of the component industry, the memory chip test equipment has also made great progress. So, how much do users know about the memory chip test equipment?
In order to simplify the test steps, reduce the complexity of the test, improve the test efficiency, and reduce the test cost, the memory chip test device realizes the convenient and quick test of all the above memory chips under the same platform. The memory chip test device realizes the accurate operation of accessing various memory read/write timings based on the external bus by appropriately adjusting the external bus timing according to the unique read/write timing access characteristics of the above various memories.
The memory chip test equipment 40-bit NAND FLASH and NIOSII are bridged by ABUS (FPGA) to completely convert the timing of the external bus into the operation timing of NAND FLASH. The 40-bit NAND FLASH chip is composed of five independent 8-bit NAND FLASH chips. The external IO ports of the five 8-bit devices are spliced into 40-bit external IO ports, and the respective control lines (NCLE, NALE, NRE, NWE) are connected together to form a set of control lines (NCLE, NALE, NRE, NWE). The chip selects are independently derived into NCS0-NCS9, and the busy signals are independently derived as R/B0-R/B9. The memory chip test equipment SRM module and NIOSII are connected through ABUS to achieve correct timing read and write operations. During the test, only 8 bits were tested at a time, and all the space tests were completed in 5 times.
The memory chip test equipment is developed using the LNEYA refrigeration heating temperature control advantage. The high configuration parameters in terms of performance are more conducive to the operation of the memory chip test equipment.
(This article source network, if there is infringement, please contact delete, thank you.)
Related recommendations
-
What Are The Characteristics Of The Reactor Heating System?
1550Wuxi Guanya LNEYA reactor heating system The liquid circulation of the whole system is closed, the system has an expansion vessel, the expansion vessel and the liquid circulation are adiabatic, do not participate in the liquid circulation, only th...
View details -
How To Choose The Screw Type Water-Cooled Chiller
2278Compared with the similar chillers, the screw type water-cooled chiller has many advantages. We as one of the top chiller manufacturers share you more. 1. The temperature of the heat conducting liquid can be adjusted to any temperature you want, a...
View details -
Characteristics of the evaporator of LNEYA screw chiller
2764The amount of cooling capacity of the screw chiller is directly related to the energy consumption and operational economics of the entire unit, which is worthy of attention. Especially when designing a cold station, there is no single chiller in t...
View details -
How to solve the problem of poor cooling performance of the heat transfer oil circulation system?
2067Some heat-conducting oil circulation systems will not be as good as before after 3 months of use. At this time, it is recommended to contact the professional after-sales department to check the user's power supply and whether the equipment is norm...
View details
工業冷水機製造商 LNEYA Taiwan