Operation and Maintenance of Small Water Chiller Units
2. Air-cooled module internal filter, in order to better filter impurities in the water system, the protective plate heat exchanger is generally more than 40 meshes, that is to say, its filter is more dense and finer than other brands. The advantage of this method is that it can filter impurities better, and the disadvantage is that the number of cleaning increases. But compared with the air-cooled module machine, the closed circulating water system can better ensure the cleaning of the water system in the future as long as the filters are cleaned in time during the initial operation.
3. Inspection and cleaning of end filters. Water filters are installed in both air conditioning boxes and fan coil units at the end. These water filters need to be checked and cleaned, which is also an indirect reason affecting the water system and can improve the cooling effect of the end.
4. We can’t start it forcibly. We are used to turning it on when something goes wrong. In fact, it is a serious operation error for water chiller, especially the frequent power failure and reset of the chiller, which results in the failure of protection, just like a car with frequent high water temperature failure and failure to deal with it, which eventually leads to the breakdown.
Our company provides small water chiller units, welcome to buy!
Related recommendations
-
Ultra-low temperature freezer power supply and electronic control instrument system description
2273Ultra-low temperature freezer needs to be tested after a long time of use. What should be paid attention to when the power supply and electronic control instrument system are inspected? Check the ultra-low temperature freezer power supply and the ...
View details -
How to choose low temperature and high temperature simulation equipment for material aging test?
2116Material aging testing is used in many industries, but how to choose high-quality low-temperature and high-temperature simulation equipment is very critical, because temperature plays an indispensable and important role in the testing process. LNE...
View details -
Closed Refrigeration Heating Circulator Daily Maintenance Manual
2637The closed refrigeration and heating circulators of different manufacturers have a certain life span. Reasonable and correct operation and maintenance of the closed refrigeration heating circulator can effectively extend the service life. The user...
View details -
Working principle of refrigeration and heating thermostat for chemical industry
2009In the selection process of the special refrigeration and heating thermostat for chemical industry, the heating power and the pressure and flow rate of the heat transfer medium are also factors to be considered. Different raw materials have differ...
View details