What are the characteristics of the pressure of industrial water chillers
Industrial water chillers are one of the
most popular equipment in the machinery and equipment industry. For this
reason, the editor of LNEYA specially compiled relevant pressure instructions
to help everyone better understand industrial water chillers.

The reference value related to the pressure
resistance of industrial water coolers and piping system components refers to
the design given pressure related to the mechanical strength of the piping
components. The nominal pressure is generally expressed by PN. The nominal
pressure of the special chiller for the laboratory-the compressive strength of
the product at the reference temperature, expressed in PN, the unit: MPa, the
reference temperature: the reference temperature is different for different materials,
for example, the reference temperature of steel is 250°C, The
nominal pressure is 1.0Mpa, which is recorded as: PN 1.0 Mpa.
The working pressure of the industrial
water chiller refers to the large pressure required for the operation of the
pipeline system according to the high working temperature of the pipeline
conveyed by the medium at all levels. The working pressure is generally
expressed in Pt.
The design pressure of an industrial water
chiller refers to the large instantaneous pressure that the water supply piping
system acts on the inner wall of the pipe. Generally, the sum of the working
pressure and the residual water hammer pressure is used, and the design
pressure is generally expressed in Pe.
The test pressure of an industrial water
cooler refers to the pressure that the pipeline, container or equipment must
reach for the pressure resistance and air tightness test requirements. The test
pressure is generally expressed by Ps.
The nominal pressure of industrial water
chillers is for the convenience of design, manufacture and use, and is a
nominal pressure artificially specified. The unit of this nominal pressure is
actually the pressure, and the pressure is the common name in Chinese, and the
unit is “Pa” instead of “N”. The nominal pressure of the
pressure vessel refers to the nominal pressure of the pressure vessel flange.
The nominal pressure of the pressure vessel flange is generally divided into 7
levels, namely 0.25, 0.60, 1.00, 1.60, 2.50, 4.00, 6.40MPa.
Summarize
Generally speaking, the pressure of
industrial water chillers can be divided into: test pressure>nominal
pressure>design pressure>working pressure. If you have any other
questions, you can consult us and send an email to sales@lneya.com
Related recommendations
-
The significance of temperature in IC testing
3087Every integrated circuit (IC) goes through two type of tests before it can be sold and used to build a product: the first is called a wafer test; the second is called final test. With the improvement of integrated circuit electrical test technolog...
View details -
Failures of Heating Cooling Circulators
1919The heating cooling circulator can be used in many chemical pharmaceuticals and laboratories. Then, how to solve the failures of the heating cooling circulator? Failure of circulating pump The failure of the circulating pump is generally the heat ...
View details -
Won the “Excellent Supplier of Reactor Temperature Control Equipment in 2021”
4931LNEYA was awarded the "2021 Excellent Supplier of Reactor Technology" by Corning, a Fortune 500 company in the United States. Since 2015, LNEYA has won this award for 7 consecutive years. Therefore, in the reactor manufacturing industry, we have ...
View details -
Simulation control of temperature change in the cooling and heating temperature control system of th
1676Industrial cooling and heating temperature control system is a temperature control equipment used in the cooling and heating process of reaction kettle in the pharmaceutical and chemical industry. What are the characteristics of lneya's equipment?...
View details
工業冷水機製造商 LNEYA Taiwan