Performance description of recirculating chiller for bioreactor
The recirculating chiller is suitable for
the high and low temperature reaction of various stainless steel, enamel,
titanium alloy reactors, emulsifiers, injection molding machines, mixing
vessels and various bioreactors. Other bioreactors in different industries are
special recirculating chillers. , Wuxi Guanya LNEYA adopts a fully enclosed
pipeline design, which can achieve higher efficiency in terms of operating
effects.

1. Fully enclosed system
During the operation of the special
recirculating chiller for bioreactor, only the heat transfer medium
participates in the circulation, and the temperature of the expansion tank is
always maintained at room temperature 60℃, which avoids the
problems caused by the air entering the circulation system.
2. High temperature cooling
The compressor can be directly used for
refrigeration at high temperatures (using the single-machine self-cascade
refrigeration technology), and it can be used for high-temperature exothermic
reactions, such as 200 ℃, without changing the medium, only the compressor can control the
temperature and take away excess heat. .
3. Wide temperature range
The special recirculating chiller for
bioreactors can achieve system temperature control in a wide range of -120℃~300℃ with a
single heat transfer medium. However, a single compressor refrigeration
technology can reach a low -150°C, and is smaller in size and easier to lift.
4. Dynamic temperature control technology
The temperature measurement points at the
liquid inlet and outlet and the material will transmit temperature information
in real time. When the temperature difference is large, the control system will
immediately issue an exothermic and endothermic reaction to control the
temperature of the heat transfer medium within ±0.3°C.
5. Pipeline circulation system
Pipeline heaters and plate heat exchangers
increase the power density ratio, reduce the amount of heat transfer medium
used, and improve the response speed of the system’s temperature control.
6. Heating protection
After the control protection of the
controller body fails, if the temperature exceeds the temperature value set by
the deviation protector in the system, the power supply of the solid state
relay will be cut off, and the independent temperature limiter will play its
role after the protector fails. With this triple protection, there will be no
high temperature overshoot.
The quality of equipment manufactured by
different recirculating chiller manufacturers is different, and everyone needs
to be aware of this.
Related recommendations
-
What is a laboratory glycol chiller What should I pay attention to
2368The laboratory glycol chiller is a common cooling equipment in the laboratory. It is generally used to achieve the temperature requirement of the cold source. What are the benefits? 1. Why choose a laboratory glycol chiller: The single-machine s...
View details -
Detailed Introduction of Air Cooled Chiller Equipment
1954LNEYA refrigeration has accumulated over 10 years of cooling supporting application experience. According to different application fields and service conditions, it has developed a variety of types of cooling chillers, including air cooled chiller...
View details -
Temperature Control Soultion for Wafer Cleaning Solution in Semiconductor Industry
2402With the rapid development of semiconductor technology, the requirements for wafers are getting higher and higher, making clean wafer surfaces more and more important for the manufacturing of semiconductor devices. In the wafer manufacturing proce...
View details -
Glycol chiller installation requirements
2113In the summer, the use of glycol chillers is relatively frequent. Efficient glycol chillers are also needed. Therefore, when installing glycol chillers, they need to be installed on a smooth and tidy floor. Why choose a smooth ground when installi...
View details
工業冷水機製造商 LNEYA Taiwan