Small hot and cold shock test box use note
Small thermal shock test chamber is non-explosion-proof product (explosion-proof needs to be customized), please do not use it in the environment with flammable or explosive gas. In order to avoid small thermal shock, the test box is faulty, please provide rated voltage. Power supply within range. To prevent electric shock or malfunction and malfunction, do not turn on the power before installation and wiring are completed. Please try not to open the test box door during work. If it is opened at high temperature, it may cause burns to the operator. Opening at low temperature may cause frostbite to the staff and may cause the evaporator to freeze and affect the cooling effect. If it must be opened, please do a certain amount of protection work, prohibit unauthorized disassembly, processing, modification or repair of small thermal shock test box, otherwise there will be abnormal action, electric shock or fire.
The danger of disaster.
The vents of the small thermal shock test chamber should be kept open to avoid malfunction, abnormal operation, reduced life and fire. If the machine is damaged or deformed when unpacking, please do not use it. Be careful not to let dust, wire ends, iron filings or other things enter during machine installation, otherwise malfunction or malfunction will occur. Wiring must be correct and must be grounded. Failure to ground may result in electric shock, malfunction or malfunction, abnormal display or large measurement error.
The small thermal shock test box needs to check the terminal screws and the fixing frame regularly. Please do not use it in loose condition. During operation, the power input terminal cover must be installed on the terminal block to prevent electric shock. When the instrument is in operation, the safety should be fully considered before the operation of modifying the settings, signal output, starting, stopping, etc., and the wrong operation may cause damage or malfunction of the working equipment. Please wipe the meter with a dry cloth. Do not use alcohol, gasoline or other organic solvents. Do not splash water on the meter. If the meter is immersed in water, stop using it immediately, otherwise there is danger of electric leakage, electric shock or fire. Internal parts have a certain life span. For continuous and safe use of the instrument, please perform regular maintenance and maintenance. When disposing of this product, please dispose of it according to industrial waste.
We should pay attention to the use of attention points, so as to avoid the failure of the small thermal shock test chamber during use and improve the efficiency in operation.
Related recommendations
-
Function of Evaporator in Air Cooled Chiller
1935The air-cooled chiller adopts the air cooling mode, which eliminates the essential cooling tower, cooling water pump and pipeline system of the cooling water system, avoids the condenser scaling and water pipe blockage in areas with poor water qua...
View details -
Measures for stable operation of short-range molecular distiller
1878If the short-range molecular distiller is inefficient during operation, it will affect the use of the associated refrigeration heating temperature control system. How does the short-range molecular distiller maintain stable operation? If the steam...
View details -
What aspects should be paid attention to when using laboratory cryogenic refrigeration circulators?
1907The compact circulating cooler is an economic model for routine laboratory applications. The instrument is cooled in the temperature range of -10 or 0°C to +40°C, and the temperature control accuracy can reach ±0.5°C. It is a good way to replace e...
View details -
Classification and Application of Industrial Water Chillers
2236In lots of industrial production processes, it is difficult to obtain high efficient industrial production efficiency if there is no industrial water chiller to provide a low temperature production environment. Therefore, industrial water chil...
View details
工業冷水機製造商 LNEYA Taiwan