Operation Precautions for ZLF/SR Series Reactor Temperature Control Equipment
The temperature control equipment of the reaction kettle adopts the PID control method, which greatly improves the temperature control accuracy of the whole machine. The microcomputer for cooling or heating will automatically switch to work according to the temperature setting, which simplifies the operation procedure and avoids the damage to the machine due to misoperation.
1. The fully enclosed pipeline system reduces the oxidation of heat transfer oil and is equipped with a unique cooling function. The heat transfer oil will inevitably produce oil mist when it works at high temperature. If it is not cooled in time, its service life will be greatly shortened. With this cooling function not only prolongs the service life of the oil but also reduces the flow of circulating pressure.
2. At present, it is widely used in the pharmaceutical and chemical industry, and the specific size can be distinguished according to the model. Like general equipment, it also needs to be carefully maintained during use.
3. If it is not running, if only the cooling water tower is needed for cooling, it is necessary to turn off the water source for the temperature control of the TCU reactor, and dispose of the water in the internal components and pipes of the TCU reactor temperature control, and pay attention to avoid the temperature control of the TCU reactor. The residual liquid inside will corrode the internal components of the equipment. At the same time, you need to pay attention to the temperature of the equipment. Do not place it at too low temperature to avoid frost heaving copper pipes at low temperatures.
4. It is necessary to check whether each part inside the temperature control equipment of the reactor is worn or not. If any wear is found, please replace the parts in time. In addition, the fan of the reactor temperature control equipment should always be kept in a clean state to avoid dust blockage.
The above content is about the operation precautions of LNEYA’s TCU multi-reactor temperature control equipment. If you are interested and would like a quote, you can contact sales@lneya.com.
Related recommendations
-
What Are the Features of the Glycol Refrigeration System
2037The difference between the glycol refrigeration system and the general refrigeration system is that the glycol solution is used as refrigerant to run the refrigeration system. The glycol refrigeration system is widely used. It can be used in many ...
View details -
What are the installation requirements for lithography chillers?
2173In order to ensure the reliable and normal operation of the chiller of the lithography machine and prevent the failure of the chiller caused by improper water distribution pipeline construction, the following matters should be paid attention to wh...
View details -
How to choose the right hot and cold circulator?
1963The hot and cold circulator is widely used in the pharmaceutical and chemical industry to provide users with hot and cold controlled, uniform temperature and constant temperature. It can also be directly equipped with reactors, reactors, etc. fo...
View details -
Environmental Conditions for Installation of Air Cooled Chillers
2001As we all know, the installation of most machines needs to match the environment and conditions. Of course, our industrial air-cooled chillers are no exception. If the air-cooled chiller is not installed for the first time, it will bring a lot of ...
View details
工業冷水機製造商 LNEYA Taiwan