The Use of Electronic Expansion Valve in Low Temperature Chiller Systems
In the low temperature chiller system, the electronic expansion valve plays a key role in controlling the operating power of the system in cooperation with compressors, condensers, evaporators, water-cooled screw chillers, air-cooled screw chillers, cryogenic screw chillers, central air-conditioning units, chillers, water-cooled chillers and air-cooled chillers. Its operation situation will determine the practical refrigeration ability and control accuracy of the low temperature chiller system. However, most chillers use electronic expansion valves or thermal expansion valves as a saving arrangement of system. Controlling the superheat of the compressor inlet is most primary. However, due to the positioning in this planning, the electronic expansion valve can not fully exert the control efficacy of system accuracy. During the operation of low temperature chiller system, control can complete the optimal output control of system cooling capacity, but as is always the case, it can’t be completely exerted to output control system cooling capacity when the temperature is close to the equipment policy. the accuracy of the system can’t be ensured. Although the precision has been improved when using the method of PID control, as a whole, there is still a lot of room for improvement.
Equipment and Planning of Electronic Expansion Valve
In the low temperature chiller system, the electronic expansion valve is generally used as a general saving arrangement to control the superheat of compressor. It is usually equipped between the evaporator inlet and the condenser outlet. According to the superheat of compressor inlet, the size of the adjustable opening is analyzed and judged in real time, and the optimal control of superheat is completed to reach the optimal output of system cooling capacity. However, when the control needs to be accurate , due to the constraints of superheat, the best ability of refrigeration output control is often not brought into play, and the system temperature control accuracy is poor.
Related recommendations
-
What are the functions of the reactor temperature control system?
1925The reactor temperature control system is equipped with various reactors for high and low temperature reflection of liquid and solid. The temperature control system of LNEYA reactor adopts fully closed circulation pipeline, which is efficient in o...
View details -
Common faults of plate heat exchangers in new energy vehicle inspection
2580The reason for the excessive pressure drop of the new energy vehicle detection is that the running system pipeline is not properly purged, especially in the newly installed system pipeline, many dirt (such as welding slag) enters the interior of t...
View details -
Necessity Of New Energy Electric Vehicle Battery Test System
1715The battery performance of new energy vehicles directly determines the experience of new energy vehicle end users. The electric vehicle battery test system needs to test the performance reliability of new energy vehicle batteries. With the develop...
View details -
Characteristic Analysis of Air Cooled Industrial Chiller
1736Industrial air-cooled chillers are generally integral machines, that is, evaporator, compressor and condenser are made together. For a slightly high-power air-cooled industrial chiller, the heat dissipation of the condenser cooling fan needs to be...
View details
工業冷水機製造商 LNEYA Taiwan