Precautions for non-use of reactor water-cooled chiller shutdown
When the reactor water-cooled chiller has
complete accessories, in actual use, it is necessary to provide it with regular
rest time. In order to maintain stable performance of the chiller during
long-term operation, users need to master the method of stopping operation
according to actual use requirements to reduce excessive wear and tear of the
equipment.

1. When it is necessary to shut down, first
consider ensuring that the reactor water-cooled chiller is within the shutdown
range, and then perform all shutdown operations. In order to avoid the
generation of high pressure, the user needs to close the suction shut-off valve
and stop the compressor.
2. After the compressor of the chiller is
shut down, the oil pump needs to be operated. Return the slide valve of the
freezer to the 0 mark position, so that the load reduction reaches zero. At
this time, the oil pump will immediately stop all operations.
3. For the reactor water-cooled chiller,
the operation of the water pump and the cooling water tower needs to be stopped
in the later stage. After stopping such devices, you can turn off the entire
power supply and complete the entire shutdown process. Ensure that the
reactor’s water-cooled chiller is in a shutdown state.
Precautions for the shutdown of the
water-cooled chiller of the reactor:
1. If the machine is shut down for a long
time, special treatment is required. Including the condenser and the
evaporator, all refrigerants need to be pumped into the condenser, and all
water sources must be discharged at the same time to avoid corrosion and other
problems.
2. After the shutdown is completed, various
accessories need to be carefully tested. The shutdown process is special, and
the correct shutdown procedure can prolong the service life of the equipment.
For long-term closed reactor water-cooled
chillers, careful testing is required to ensure that the equipment is kept away
from various corrosive substances. When our LNEYA equipment is delivered to the
user, there will be a detailed instructions for use. The content includes the
handling methods and precautions of the water-cooled water chiller at the use
site, in order to reduce equipment failure and protect the user For the
efficiency of use, please contact us sales@lneya.com for details.
Related recommendations
-
How to solve the shortage of cooling in the semiconductor cooling cycle system
2092The semiconductor cooling cycle system is a device for cooling the semiconductor heat-generating part in the refrigeration equipment. If the cooling capacity of the LNEYA semiconductor cooling circulation system is insufficient during operation, i...
View details -
How to Choose Chiller and Injection Moulding Machine?
2021A. First way: The 1HP water-cooled chiller can be equipped with 80 tons locking force injection moulding machine, and the temperature can be controlled at 5-10 degrees. The 1HP water-cooled chiller can be equipped with 100 tons mould-locking force...
View details -
The influence of the evaporator of the semiconductor thermostat on the refrigeration effect
1850Different models of semiconductor thermostat equipment have different options for evaporation. According to different models, the choice of evaporator is different. For example, box-type semiconductor thermostat equipment uses water tank coil type...
View details -
The Advantage Parameter Explanation Of The Walk-In Lab Water Chiller
1736In the experimental equipment, the walk-in lab water chiller is used for all kinds of electronic components in high and low temperature or hot and wet environment to test the requirements of various performance indicators. It is generally applicab...
View details
工業冷水機製造商 LNEYA Taiwan