Workflow and Equipment Composition of Oil Refining and Dewaxing
The oil dewaxing process is based on the melting point difference between the wax and the oil and the solubility of the wax in the oil becomes smaller as the temperature decreases, and the crystalline wax is precipitated by cooling. Then through the filter separation surface to achieve the purpose of wax oil separation.
The dewaxing process is as follows:
Refined oil – pre-cooling – crystallization – crystal growth – filtration – refined oil
Pre-cooling tank:
Due to the high temperature of the refined oil wax, use the pre-cooling tank to cool the oil temperature in advance to reduce the cooling time of the crystallization tank.
Crystallization tank:
The cooling oil is poured directly into the crystallization tank for crystallization. When crystallizing, the stirring speed is slow, generally 5-8 rpm, so that the oil temperature is cooled evenly, and the ideal crystallization effect is achieved.
Crystal jar:
After crystallization, crystal growth is carried out, which provides conditions for the growth of wax fat crystal grains. The temperature is generally controlled between 15-25°C.
filter:
The well-raised oil is first filtered through its own self-pressure, and then the frequency conversion screw pump is started when the filtering speed is slow, and it is filtered when it is adjusted to a certain speed, so as to achieve the separation of oil and wax.
The main components of the complete set of dewaxing equipment are: crystal growth crystallization tank, filter, dewaxing oil tank, wax paste tank, refrigeration unit, frozen brine pool primary gear pump, pipeline pump and other equipment.
When oil equipment manufacturers design the oil production line plan, they will choose whether to configure dewaxing equipment according to factors such as the type and grade of oil. Provide customers with suitable design solutions by understanding their needs.
Related recommendations
-
The advantages of water cooled chiller you need to know
2158Industrial chillers can be generally divided into water-cooled and air-cooled according to the type of refrigeration. The heat exchange medium of Water Cooled Chillers is water.LNEYA has designed and developed a new type of temperature control equ...
View details -
Refrigeration and heating temperature control system for multiple reactors
18581. There are some differences in the quality and configuration of the refrigeration and heating temperature control systems of multiple reactors from different manufacturers. Some equipment will have some noise during operation, and the noise is ...
View details -
Chemical reaction exothermic or endothermic temperature dynamic compensation system
2062In the chemical laboratory, pilot plant and reaction process, temperature control requires the use of dynamic temperature control systems. When controlling the reactor, the exothermic and endothermic reactions must be compensated with high speed a...
View details -
Maintenance knowledge of 12HP (8.9kW) low temperature chiller
2235The user can arrange the operator to learn about the daily maintenance knowledge of the 12HP (8.9kW) low temperature chiller after purchase. It can not only improve the company's product quality, improve production efficiency, but also extend the ...