How to deal with the installation of the hot and cold integrated control machine?
Since the thermocouple’s thermal inertia causes the meter’s indicated value to lag behind the measured temperature, this effect is particularly pronounced when performing rapid measurements. Therefore, thermocouples with thinner thermal electrodes and smaller protective tube diameters should be used whenever possible. The protective tube can even be removed when the temperature measurement environment permits.
In the use of hot and cold integrated control machine, usually use materials with good thermal conductivity, thin tube, small inner diameter protection sleeve, in the more precise temperature measurement, use unprotected sleeved bare wire thermocouple, but thermocouple It is easy to damage and should be corrected and replaced in time.
Due to the measurement lag, the amplitude of the temperature fluctuation detected by the thermocouple is smaller than the amplitude of the furnace temperature fluctuation. In order to accurately measure the temperature, a thermocouple with a small time constant should be selected. The time constant is inversely proportional to the heat transfer coefficient. It is proportional to the diameter of the hot end of the thermocouple, the density of the material, and the specific heat. If the time constant is to be reduced, In addition to the thermal coefficient, the error introduced by the insulation of the cold and heat integrated control machine is poor.
The hot and cold integrated control machine protects the tube and the wire plate from excessive dirt or salt residue, resulting in poor insulation between the thermocouple and the furnace wall, which is more serious at high temperatures, which not only causes the loss of the thermoelectric potential but also introduces interference. The error caused by this can sometimes reach Baidu.
The above installation failures should be avoided as much as possible to reduce the error rate of the integrated heat and cold control machine and save the operating cost of the enterprise.
Related recommendations
-
Cooling method for semiconductor testing chiller to meet temperature control requirements
2494The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to stabilize chemical reactions; the electronic manufact...
View details -
What are the main hazards of the reaction kettle in the reactor intelligent temperature control syst
2143The intelligent temperature control system of the reactor is used in various chemical fines. With the constant attention of the industry safety issues, some risk factors of the intelligent temperature control system of the reactor should be avoide...
View details -
What are the reasons for the power consumption of large-size refrigeration units?
1886During the operation of large-size refrigeration units, the cooling capacity and working conditions are the main issues of power consumption, but in order to avoid some unnecessary power consumption, we need to understand clearly. When the scale o...
View details -
Cooling heating temperature control system SUNDI series thermal fluid filling instructions
24631. Refrigeration heating temperature control system SUNDI series equipment before the heat conduction filling, the heat transfer liquid inlet of the heating refrigeration circulator and the heat transfer liquid outlet of the upper end of the react...
View details
工業冷水機製造商 LNEYA Taiwan