Cooling and heating of the reactor and the principle of use
Cooling and heating circulator thermostats are commonly used with glass reactors for biochemical instruments. They are widely used in modern fine chemicals, biopharmaceuticals, scientific research and experiment industries. They can be concentrated, distilled, Will stay, separate and purify the reaction. In the production process, whether it is a double-layer glass reactor or a single-layer glass reactor, the refrigeration heating temperature control system can generally complete high temperature, low temperature, and vacuum reaction experiments at the same time. Under constant temperature conditions, in a closed container, the refrigerating and heating circulator can be combined with a glass reactor to carry out stirring and reaction under normal or negative pressure, and can control the evaporation and reflux of the reaction solution.
One of the methods of obtaining high temperature is steam heating. When the cooling and heating temperature control system is matched with the glass reactor, the heating temperature is required to be below 100°C, and the glass reactor can be heated by steam. In this method, the equipment is heated with subatmospheric steam. When the temperature is required to be in the range of 100°C to 180°C, saturated steam can be used; when the temperature is required to be higher, high-pressure superheated steam can be used for heating.
Different manufacturers’ isolation reactor heating circulators are designed with different temperature ranges and media. It is necessary to select the appropriate media according to the available media of the equipment. Common media include water, oil, refrigerant, etc. The cooling process of the equipment is to use the refrigerant to absorb the excessive heat of the equipment and evaporate it to achieve the purpose of temperature difference.
The principle of temperature control of the matching reactor is indirect temperature control. The temperature is controlled by the heat transfer oil or other medium in the jacket of the reactor and the coil, and the temperature of the reactor wall is raised and lowered through the medium.
Our LNEYA heating circulator can set the working temperature and alarm temperature on the equipment digital display, press the heating option, after the indicator light is on, you can adjust its heating power through power selection; when using heat transfer oil, it is recommended to directly contact the equipment The manufacturer purchases the corresponding heat transfer oil. When using it, the heat transfer medium cannot contain water, otherwise it will cause equipment failure.
Related recommendations
-
Selection and installation of the expansion valve for recirculating chillers
1933Regarding today's topic, we have the following analysis. The selection of expansion valve plays an important role in the performance of the recirculating chiller refrigeration system. The correct choice of expansion valve will maximize the use o...
View details -
Types of Environmental Tests
2135The environmental chamber is one of the many types of experiments used in scientific research, product development, production and evaluation. The fundamental difference between environmental tests and other tests is that there are specific requir...
View details -
Introduction Of Low Temperature Refrigeration Equipment Series-low Temp Process Chillers
1895Thermoacoustic refrigeration technology is a new refrigeration method with wide application prospects. It is one of the major advances in refrigeration and cryogenic technology in the past 30 years. Thermoacoustic engine uses thermoacoustic effect...
View details -
Several Attention Aspects of Ultra Low Temperature Freezer
2109The performance of ultra low temperature freezer will be reduced naturally due to long-period application in all fields. Thus, Guanya Refrigeration Technology Co., Ltd, leader in ultra low temperature freezer manufacturers has to remind every user...
View details
工業冷水機製造商 LNEYA Taiwan