Explosion-proof cryogenic refrigeration unit icing, do you know what is going on?
When using an explosion-proof cryogenic refrigeration unit, many users do not know how to solve the problem of icing and frosting. In fact, the professional can tell you with certainty, no. The two causes are different, so the processing method is different. If you want to solve the problem of icing in explosion-proof cryogenic refrigeration units, you must first find the problem. Let’s share some of the experience in this area.
In the actual use of explosion-proof cryogenic refrigeration units, many customers do not like the internal temperature of the explosion-proof cryogenic refrigeration unit. The icing is definitely related to the low temperature. If the temperature of the refrigeration unit of the explosion-proof cryogenic refrigeration unit is too low, then there is a knot. Ice conditions.
The temperature of the refrigerating room should generally be set between 4 and 8 degrees. Most of the explosion-proof cryogenic refrigeration units can be directly adjusted by the display of the computer thermostat. If it is a mechanical thermostat, it should be based on the seasonal temperature. High and low reasonable adjustment of gear position, the gear should be adjusted to 1-2 files in summer, 3 in spring and autumn, 4-5 in winter, keep the temperature of the freezer at around 18 degrees, the cold room The temperature is between 0-10 degrees and between 4-8 degrees. This breaks the conditions of icing, so it will not happen.
There is also an icing condition, that is, there must be water or water mist, otherwise the explosion-proof cryogenic refrigeration unit will not freeze. So how does water or mist enter the explosion-proof cryogenic refrigeration unit?
That is, the seal of the explosion-proof low-temperature refrigeration unit door seal is not strict or the door opening is frequent or the door opening time is too long. The door seal of the explosion-proof low-temperature refrigeration unit is an important component. If the seal is not strict, the cold air in the refrigerator room will be lost, resulting in outdoor Air entering should be repaired and replaced in a timely manner. When using the explosion-proof cryogenic refrigeration unit, it is also necessary to open the door and close the door quickly, and do not frequently open and close the door.
Have you learned the icing knowledge of these explosion-proof cryogenic refrigeration units? To solve these icing problems, we must pay attention to and solve them from the usual details.
Related recommendations
-
Description of industrial grade SUNDI heating and cooling temperature control system
2431The industrial-grade heating and cooling temperature control system SUNDI series is a device developed and manufactured by LNEYA using its own advantages in the field of cooling, heating and temperature control, and supports customized services in...
View details -
Operation Instructions of Heating Cooling Circulator
2077Heating cooling circulator is a process that refrigerant transfers heat from low temperature state to high temperature state, so that its cooling can reach the state of low temperature environment, thus maintaining the low temperature state and re...
View details -
Characteristics of the evaporator of LNEYA screw chiller
2764The amount of cooling capacity of the screw chiller is directly related to the energy consumption and operational economics of the entire unit, which is worthy of attention. Especially when designing a cold station, there is no single chiller in t...
View details -
What should I pay attention to when replacing a water-cooled chiller compressor
1942Once the compressor of the water-cooled chiller fails, the compressor needs to be replaced in time, but the replacement of the compressor is not as simple as imagined. Before the water-cooled chiller compressor is replaced, the reasons for the da...
View details
工業冷水機製造商 LNEYA Taiwan