The safety of heat transfer oil in water-cooled chillers
In order to achieve better operating efficiency, water-cooled chillers need to choose branded heat transfer oil, but you need to pay attention to safe placement, a little carelessness will cause adverse effects.
Although the heat transfer oil of the water-cooled chiller has a higher boiling point, it is still a flammable liquid. Therefore, you should pay attention to safety when using it. Improper use may cause fire. The cause of the fire is caused by leakage. There are four main types of leakage and fire:
A. Fire in the heat preservation area.
Common misfire types in organic heat transfer oil systems. The heat transfer oil leaks at the instrument connection and penetrates into the heat preservation area. Then, in the presence of air, the circulating liquid and pipe heat will heat the heat conduction oil and gradually oxidize the liquid, causing the heat preservation area to be ignited and cause a fire.
B. Fire caused by pipeline leakage or burst.
The leakage or burst of the pipeline caused the heat transfer oil to flow into the hot gas flame zone and cause a fire.
C. The flash point causes a fire.
The factors that cause the flash point fire are higher than the low flash point temperature of the heat transfer oil, and there are heat transfer oil, air and fire sources at the same time.
D. Fire caused by process raw materials:
The main reason is that the heat-conducting oil leaks into the heating system, and its process raw materials are easily oxidized and have oxidizing substances, which causes a fire.
In addition to the above four types of fires, more attention should be paid to the use of gas-phase systems. If a large amount of heat transfer oil vapor leaks, aerosol mist may be formed. This mist may cause explosion and combustion in the air when exposed to an open flame.
Therefore, the heat transfer oil of water-cooled chillers is related to its operating efficiency and safety, so it is necessary to do a good job in the repair and maintenance of the hot oil system to prevent the leakage of the heat transfer oil.
Related recommendations
-
Structural Characteristics of Industrial Recirculating Chiller
1614In the chemical reaction, there are strict requirements for the reaction temperature. It is necessary to raise the temperature to an appropriate temperature to carry out the chemical reaction smoothly. After the reaction, the temperature in the re...
View details -
Cooling system of liquid-cooled energy storage cabinet-chiller
1976With the development of new energy technology, the application of containerized energy storage systems in new energy, photovoltaic, and electric energy stations has increased. If the temperature of the energy storage battery pack is not well contr...
View details -
Reactor heating hot cooling system instructions
2043The reaction heating and cooling system of the reaction kettle realizes the material reaction equipment during the reaction process of the material. The heating and cooling system of the LNEYA reaction kettle needs to pay attention to the reaction...
View details -
Control method for semiconductor test chiller to meet temperature requirements
2114The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to make chemical reactions proceed stably; the electronic...
View details
工業冷水機製造商 LNEYA Taiwan