Theory of Ice Flow, Ice Water Quality, Flow and Pressure of Ice Water Machine
The softening of water is also an important problem in the process of using chillers.The pH value of water also needs to be continuously observed. The optimum pH value should be equal to 7. The pH value greater than 7 will cause terrible corrosion. If no measures are taken, fouling will be built in the evaporator and die, which will play an insulating role, and the energy conversion effect will be reduced by 30% in severe cases. Obviously this requires consideration of the softening of hard water.
The most effective method is to configure an electronic hard water softener in the system, which is designed and manufactured separately from the exchange principle. Softeners of different specifications can be configured according to different flow rates, which can be directly connected to the circulating water pipeline.
Generally, the cost of water treatment softener is not too high, and a certain proportion of scale removal agent can be added to the periodic circulation system. Generally, when the injection moulds are cooled and the pressure of ice water is 0.1-0.2 mpa, the requirements can be met. When the pressure requirement is higher than 0.2 mpa, it is necessary to plan separately in order to use the corresponding pressure from the pump to meet the need of water supply.
We are a top chiller manufacturer. Welcome to buy our products.
Related recommendations
-
What if the cooling rate of the cooling and heating temperature control system of the reactor slows
2092LNEYA cooling and heating temperature control system is a laboratory instrument and equipment for temperature control of supporting reactors in pharmaceutical and chemical laboratories and other industries. It adopts a fully closed circulation pip...
View details -
What are the causes of corrosion in industrial chillers / water chillers?
2621Industrial chillers are now widely used in various industries, but as they become more and more widely used, many problems slowly emerge. Corrosion problems are also relatively common. Because everyone does not use the standard and the maintenance...
View details -
The solution to the fully enclosed heating and cooling thermostat lack of refrigerant alarm
2333What should I do if the fully enclosed heating and cooling thermostat alarms for lack of refrigerant? I believe that many customers will encounter this problem when they use it. In fact, this is relatively simple. As long as we know the principle ...
View details -
Comparison of Three Test Methods for Low Temperature Chamber
22642. Non-heat dissipation test samples and heat dissipation test samples When the temperature of the test sample is stable during the conditional test period, the hottest spot temperature on the surface of the test sample is higher than the ambient...
View details
工業冷水機製造商 LNEYA Taiwan